| The input
section, located on the bottom panel of the tester, consists of a
group of switches which actuate the controller inputs. The switches
are conveniently labeled by function from top to
bottom.
INPUTS Per
Controller
- Call to Non Act 1 and
2
- Test A and B
- Minimum
Recall
- Walk Rest Modifier
- Manual Control
Enable
- Lamps Off
- External
Start
- 6 Spares
Per
Ring
- Max Inhibit
- Stop Time
- Force
Off
- Red Rest
- Omit All
Red
- Ped Recycle
- Max 2
Per
Phase
- Veh Det
- Ped Det
-
Hold
- Phase Omit
- Ped Omit
The output section,
mounted in the lid, is made up of a group of panel mounted LED's
that are connected to the controller outputs and when lighted
indicate which are active.
OUTPUTS Per
Controller
- Flashing
Logic
- Voltage Monitor
- 5 Spares
- Overlap A B C
D
Per
Ring
- Status Bits
Per
Phase
- Red, Yellow, Green
- Walk, Don't
Walk
- Phase On
- Phase
Next
- Phase Check
Power Interrupt
The NT-11 has a feature which
permits testing the AC power interrupt operation of a controller.
Adjustable from 0.1 to 1.1 seconds, it verifies that the controller
responds correctly to short powerline
interruptions.
Test
Points
| 24V: |
Controller 24 V power supply |
| Log Gnd: |
Controller logic ground |
| NEUT: |
Power line Neutral |
Specifications -
ABS Plastic Case
| Size: |
7" x 14" x 21" |
| Weight: |
16 pounds |
| Power: |
120 VAC 1 AMP |
| Connectors: |
NEMA Standard |
| Optional Feature: |
Phase type display |
|