BIU 130 Bus Interface Unit

The Naztec Model BIU 130 Bus Interface Unit
links the TS-2 Controller Unit to the Cabinet
I/O. It is responsible for controlling load switches, providing dimming,
receiving and isolating pedestrian calls, analyzing detector faults,
time-stamping detector calls, and providing detector resets. By design, the BIU
is free of operator contorls. The BIU performs its I/O functions based upon a
pre-wired card rack address.
Features
Meets or Exceeds all NEMA TS2 Standards
TS2 SDLC port
Less than 50mA standby current
Designed for "HOT" plugging
Socketed I/O drivers for easy maintenance
Heavy duty 200 mA output drive capability
Power brownout indication
120 Hz reference failure indication
Optional RS232 port for custom applications
Specifications
Power Specifications
18-26 VDC; 200 mA;
Less than 1.5 A Power-Up Surge
Can be inserted with power applied
Input
8 Dedicated Inputs; 24 Configurable
Inputs
Low (True) Below 4 VDC
High (False) Above 16 VDC
Greater than 50 mA Sink Current
SDLC Port 1
EIA-485 Standard Compliant; 153.6 Kbps Data Rate; SDLC Protocol
RS-232C Port
RS-232 Standard Compliant; Factory Customizable Interface
Opto-Input
Less than 3 VRMS Active (True); Greater than 6 VRMS Inactive (False)
10 MW, 1000 VAC RMS Isolation
Power LED Indicator
Short “Wink” Off Indicates 120 Hz Reference Failure
Long Period On/Off Toggle Indicates
Inadequate 24VDC Power Level
Solid On Indicates Proper Power and
Operation
Solid Off Indicates No Power
Transmit LED Indicator
Quick Blinking Indicates Proper
Communications Activity
Solid Off Indicates Communications Failure
© Copyright 2000 by Naztec, Inc - All Rights Reserved.